Control
panels for a wide variety of applications are manufactured by
Heaters Controls And Sensors. From custom control panels that
are needed to operate in minus 60ºC environments, outdoors with
high winds with control panels that are heated to prevent internal
components from freezing, or indoor laboratory control panels
that can control temperatures within a degree ramp.
Soak control panels along with programmable controllers or control
panels that are started with weekly programmable timers that
can be made to control the on time and off time of other control
panels or heaters. These control panels can control a large
number of components as required or heaters to maintain temperatures
within +/- 0.01ºC. These
custom control panels can be made to withstand wash downs with
corrosive chemicals with all components on the panel conforming
to IP 65 and NEMA 4X. Integration of components for steam booster
heaters or recirculation heaters with flow fail safe interlocks
are also available.
Control panels for extruders or multiple heaters on a single
circuit with heater current indication can be used so that any
failure or open circuit of heaters can be detected immediately
on the control panel with panel alarms for control or event
action. Control
panels with automation include temperature controls with high
temperature fail-safe alarms (FM approved,) loop break alarms,
heater break alarms, heater current indication and shorted output
device (contactor) alarms or annunciation. Custom
Control Panel Features:
- Quick delivery
- State-of-the-art technology and engineering
- Integration of temperature, level, pressure, motor and
motion control
- Hydro approved and CSA or C UL components used throughout
- NEMA 4X, NEMA 4 and NEMA 7 explosion proof panels available
- Versatile precision LAB control, plant process or plant
system engineering
- Easy adaptation to existing plant switch gear or specification
- Control panels for heaters & Heating Systems
|
| |
Custom Control
Panels Ordering Information: EXAMPLE:
CCP – SCR – 1 – S – 04 – 6 –
J – D – B CCP = Custom
Control Panel SCR power control 120 volts single phase
NEMA 4 housing 1/16 DIN temperature controller Type J thermocouple
input Digital Hi Limit & Heater Break
Alarm Type of POWER Control
SCR = SCR Power Controller MDR = Mercury Relay MEC = Mechanic
Relay VOLTAGE
1=120 volts, 2=208/240, 3=370/380, 4 = 460/480, 6=575/600
PHASE
S = Single T = Three ENCLOSURE NEMA Rating
01 = General Purpose NEMA 1
3R = NEMA 3R Weather Resistant
04 = Moisture Resistant NEMA 4
4X = Corrosion/Moisture Resistant NEMA 4X
47 = Moisture/Explosion Proof NEMA 4/7
07 = Explosion Resistant NEMA 7
12 = Dust and Oil Resistant NEMA 12 Size
of TEMPERATURE
6 =1/16 DIN, 8=1/8 DIN, 4=1/4 DIN, 3=32 DIN Type
of INPUT/SENSOR
R=RTD, 4=4 TO 20 Amps, 1= 1 to 5 VDC, X=Special
Thermocouples specify J,K,R,S,T,E,N
MAXIMUM SYSTEM kW System Power
Type of HI LIMIT
D = Digital Hi Limit FM Approved
A = Analog Hi Limit Back Panel Mount ALARMS
H = Aux. Hi Alarm (Deviation or Process) with Mechanical Relay
Fail Safe
B = Heater Break Alarm
L = Loop Break Alarm |
| |
Stock Control Panels:
Part #VOLTSKWPHControlAlmLimitSensorStkNameCP123A12031MR/
SSrYNJKRSTYCP246A24061MR/ssrYNJKRSTYCP289A2088.53MR/
ssrYNJKRSTYCP2410A240103MR/ssrYNJKRSTYCP2420A240203MR/
ssrYNJKRSTYCP277A270 6.71MR/ssrYNJKRSTYCP3816A380163MR/
ssrYNJKRSTYCP3830A380303MR/ssrYNJKRSTYCP4820A480203MR/
ssrYNJKRSTYCP4840A480403MRYNJKRSTYCP4880A480753MRYNJKRSTYCP6080A60025
3MR/SSRYNJKRSTYCP6050A600503MRYNJKRSTYCP6090A600903MRYNJKRSTY
The above panels have Dual display PID controllers with FUZZY logic
That can be enabled or switched off.
NOTE: MR = Mercury relay or SSR = Solid State Relay or SCR
CO = Contactor Optional
AL = High Alarm Will Isolate Secondary Relay
Works Off Main controller
Hi Limit = Digital Hi Limit Can be Installed as an option for overtemp
These are FM approved
All above Panels are with Disconnect switches and Fused for KW noted
|
| |
 |
|